Single Joist Saddle Flashing
Quickflash Single Joist Saddle Flashings
Available in 8 Sizes includes Wet Gauged & Dry Frame sizing.
Quickflash Codes 101 - 104 - Other sizes available on request.
All A Measurements include the 35mm overhang required by the building code.
| Code 101 | Code 101D | |||
| 150x50 | 140x45 | |||
| A | 185mm | 175mm | ||
| B | 50mm | 45mm | ||
| C | 70mm | 70mm | ||
| D | 50mm | 50mm | ||
| E | 10mm | 10mm | ||
| F | 30mm | 30mm |
All A Measurements include the 35mm overhang required by the building code
| Code 102 | Code 102D | |||
| 200x50 | 190x45 | |||
| A | 235mm | 225mm | ||
| B | 50mm | 45mm | ||
| C | 70mm | 70mm | ||
| D | 50mm | 50mm | ||
| E | 10mm | 10mm | ||
| F | 30mm | 30mm |
All A Measurements include the 35mm overhang required by the building code
| Code 103 | Code 103D | |||
| 250x50 | 240x45 | |||
| A | 285mm | 275mm | ||
| B | 50mm | 45mm | ||
| C | 70mm | 70mm | ||
| D | 50mm | 50mm | ||
| E | 10mm | 10mm | ||
| F | 30mm | 30mm |
All A Measurements include the 35mm overhang required by the building code
| Code 104 | Code 104D | |||
| 300x50 | 290x45 | |||
| A | 335mm | 225mm | ||
| B | 50mm | 45mm | ||
| C | 70mm | 70mm | ||
| D | 50mm | 50mm | ||
| E | 10mm | 10mm | ||
| F | 30mm | 30mm |
*Solid Plaster & Aluminium should not come in contact
Galvanised Steel
Aluminium
Colorsteel Maxam
Stainless Steel
Specifications:
- Galvanised Steel - Z450 - 0.55mm
- Aluminium - 5000 Series - 0.7mm
- Colorsteel Maxam - Ebony - 0.55mm
- Stainless Steel - 304 - 0.5mm
Refer to E2/AS1 - Tables 20, 21 & 22
Quickflash Codes 101 - 104 Single joist saddle flashings are positioned over a joist or other member that protrudes through the cladding in a direct fix or cavity situation.
An inter-storey flashing, Quickflash Codes 08 or 12 or a 'Z' flashing Quickflash Codes 20, 21, 22, 27, 28 & 29 is positioned under the saddle flashing to direct any water to the outer face of the cladding. The cladding should be sealed to the saddle flashing after installation. We would suggest a bead of MS Silicon be run up the sides of the joist and across the top about 20mm in from the outside edge to help stop capillary attraction.
For selection of the appropriate flashing material to use refer to E2/AS1 - tables 20-22.